Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4NX7

single cryogenic temperature model of DHFR

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.3.1
Synchrotron siteALS
Beamline8.3.1
Temperature [K]100
Detector technologyCCD
Collection date2011-10-25
DetectorADSC QUANTUM 315
Wavelength(s)1.115869
Spacegroup nameP 21 21 21
Unit cell lengths34.040, 44.820, 98.200
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution40.774 - 1.150
R-factor0.1405
Rwork0.139
R-free0.16930
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1rx2
RMSD bond length0.015
RMSD bond angle2.081
Refinement softwarePHENIX ((phenix.refine: dev_1328))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.190
High resolution limit [Å]1.1501.150
Number of reflections51212
Completeness [%]94.464.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5293100MM HEPES PH 7.5, 21% PEG8000, 200MM MGCL2, VAPOR DIFFUSION, HANGING DROP, temperature 293K

222926

PDB entries from 2024-07-24