Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4N5P

Thermolysin in complex with UBTLN20

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.2
Synchrotron siteBESSY
Beamline14.2
Temperature [K]100
Detector technologyCCD
Collection date2012-07-19
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.91841
Spacegroup nameP 61 2 2
Unit cell lengths92.491, 92.491, 130.891
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution34.161 - 1.250
R-factor0.1143
Rwork0.113
R-free0.13400
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)8tln
RMSD bond length0.006
RMSD bond angle1.117
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.8.4_1492))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.270
High resolution limit [Å]1.2501.250
Number of reflections90096
<I/σ(I)>42.96.2
Completeness [%]98.586.4
Redundancy12.75.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.5291.1550 mM Tris/HCl, 1.9 M CsCl, 50% DMSO, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 291.15K

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon