Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4MZN

Thermolysin in complex with UBTLN59

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.2
Synchrotron siteBESSY
Beamline14.2
Temperature [K]100
Detector technologyCCD
Collection date2012-04-24
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.91841
Spacegroup nameP 61 2 2
Unit cell lengths92.493, 92.493, 131.183
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution20.706 - 1.172
R-factor0.1169
Rwork0.116
R-free0.13820
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)8tln
RMSD bond length0.005
RMSD bond angle1.128
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.8.4_1492))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.190
High resolution limit [Å]1.1701.170
Number of reflections110592
<I/σ(I)>29.13.84
Completeness [%]99.387.9
Redundancy9.23.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.5291.1550 mM Tris/HCl, 1.9 M CsCl, 50% DMSO, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 291.15K

222624

PDB entries from 2024-07-17

PDB statisticsPDBj update infoContact PDBjnumon