Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4MTT

Ni- and Zn-bound GloA2 at low resolution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyCCD
Collection date2011-03-16
DetectorADSC QUANTUM 315r
Wavelength(s)0.95370
Spacegroup nameP 65 2 2
Unit cell lengths51.070, 51.070, 327.630
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution19.060 - 2.170
R-factor0.1771
Rwork0.174
R-free0.23480
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4mtr
RMSD bond length0.010
RMSD bond angle1.020
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareBUSTER (2.10.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]19.9902.290
High resolution limit [Å]2.1702.170
Rmerge0.1730.733
Number of reflections14584
<I/σ(I)>15.24.9
Completeness [%]99.899.7
Redundancy18.818.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION829331% PEG3350, 0.1 M Tris, 0.2 M magnesium chloride, 0.015 mM CYMAL-7, pH 8.0, VAPOR DIFFUSION, temperature 293K

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon