4MCZ
Immune Receptor
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX1 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2012-02-17 |
| Detector | ADSC QUANTUM 210r |
| Wavelength(s) | 0.95370 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 67.110, 183.430, 77.280 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 48.840 - 2.410 |
| R-factor | 0.1908 |
| Rwork | 0.189 |
| R-free | 0.23090 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.003 |
| RMSD bond angle | 1.020 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | PHASER |
| Refinement software | PHENIX ((phenix.refine: 1.8.1_1168)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 48.840 | 2.540 |
| High resolution limit [Å] | 2.410 | 2.410 |
| Rmerge | 0.158 | 0.493 |
| Number of reflections | 18843 | |
| <I/σ(I)> | 3 | |
| Completeness [%] | 100 | |
| Redundancy | 4.7 | 4.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.3 | 294 | 26% PEG 3350, 0.2M Potassium Nitrate, 0.1M Bis-Tris-Propane, pH 7.3, VAPOR DIFFUSION, HANGING DROP, temperature 294K |