Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Detector | RIGAKU RAXIS IV |
Wavelength(s) | 1.54 |
Spacegroup name | P 64 2 2 |
Unit cell lengths | 101.180, 101.180, 129.710 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 19.945 - 1.996 |
R-factor | 0.1784 |
Rwork | 0.177 |
R-free | 0.19110 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4ltd |
RMSD bond length | 0.008 |
RMSD bond angle | 1.068 |
Data reduction software | CrystalClear |
Data scaling software | CrystalClear |
Phasing software | PHENIX |
Refinement software | PHENIX ((phenix.refine: 1.8.2_1309)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | |
High resolution limit [Å] | 1.996 | 1.996 |
Number of reflections | 23514 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 277 | 10 mg/mL EmoB in 20 mM sodium acetate, pH 5, 1 mM EDTA, 1 mM DTT mixed with an equal volume of reservoir solution (0.1 M MES, pH 6.5, 1.6 M ammonium sulfate, 10% dioxane), VAPOR DIFFUSION, HANGING DROP, temperature 277K |