Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4LTB

Coiled-coil domain of TRIM25

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyCCD
Collection date2013-02-08
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)1
Spacegroup nameP 21 21 21
Unit cell lengths57.669, 83.158, 92.851
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution42.209 - 2.590
R-factor0.2082
Rwork0.203
R-free0.25720
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.009
RMSD bond angle1.165
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX ((AutoMR))
Refinement softwarePHENIX ((phenix.refine: dev_1427))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.690
High resolution limit [Å]2.6002.600
Number of reflections13941
<I/σ(I)>17.32.2
Completeness [%]96.981.4
Redundancy13.19.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2906-12% PEG 4000, 10 mM sodium acetate, pH 5.3-6.6, VAPOR DIFFUSION, SITTING DROP, temperature 290K

224572

PDB entries from 2024-09-04

PDB statisticsPDBj update infoContact PDBjnumon