Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4LQV

Thrirty minutes iron loaded frog M ferritin

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsELETTRA BEAMLINE 5.2R
Synchrotron siteELETTRA
Beamline5.2R
Temperature [K]100
Detector technologyPIXEL
Collection date2012-05-03
DetectorDECTRIS PILATUS 2M
Wavelength(s)0.954
Spacegroup nameF 4 3 2
Unit cell lengths184.084, 184.084, 184.084
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution42.230 - 1.540
R-factor0.16886
Rwork0.168
R-free0.19270
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3ka3
RMSD bond length0.005
RMSD bond angle1.012
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareREFMAC (5.7.0029)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]42.23042.2301.620
High resolution limit [Å]1.5404.8701.540
Rmerge0.1480.1480.278
Number of reflections39348
<I/σ(I)>9.513.36.1
Completeness [%]98.892.7100
Redundancy8.58.58.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP92771.6-2M magnesium chloride, 0.1M bicine , pH 9.0, VAPOR DIFFUSION, HANGING DROP, temperature 277K

224572

PDB entries from 2024-09-04