Light harvesting complex PC612 from the cryptophyte Hemiselmis virescens M1635
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX1 |
Synchrotron site | Australian Synchrotron |
Beamline | MX1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2010-07-29 |
Detector | ADSC QUANTUM 210r |
Wavelength(s) | 0.9537 |
Spacegroup name | P 63 |
Unit cell lengths | 132.081, 132.081, 64.362 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 28.929 - 1.700 |
R-factor | 0.1629 |
Rwork | 0.161 |
R-free | 0.19700 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1qgw CHAIN C |
RMSD bond length | 0.010 |
RMSD bond angle | 1.316 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: dev_1415)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 38.130 | 1.790 |
High resolution limit [Å] | 1.700 | 1.700 |
Rmerge | 0.078 | 0.790 |
Number of reflections | 70433 | |
<I/σ(I)> | 24 | 3.3 |
Completeness [%] | 98.3 | 98 |
Redundancy | 11.3 | 11.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 295 | 25% PEG3350, 0.1 M HEPES, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 295K |