4L6B
Endothiapepsin in complex with thiophen-based inhibitor SAP128
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.2 |
Synchrotron site | BESSY |
Beamline | 14.2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-07-19 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.91841 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 45.420, 73.505, 52.996 |
Unit cell angles | 90.00, 109.83, 90.00 |
Refinement procedure
Resolution | 30.000 - 1.370 |
R-factor | 0.1673 |
Rwork | 0.166 |
R-free | 0.19680 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.235 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: 1.8.1_1168)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 1.390 |
High resolution limit [Å] | 1.370 | 1.370 |
Number of reflections | 68886 | |
<I/σ(I)> | 15.6 | 2.7 |
Completeness [%] | 99.9 | 100 |
Redundancy | 3.9 | 3.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4.6 | 291 | 0.1M NH4AC, 0.1M ACETATE-BUFFER, 26% PEG4000, , pH 4.6, VAPOR DIFFUSION, SITTING DROP, temperature 291K |