4L1H
Bence-Jones immunoglobulin REI variable portion with seven point mutations
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | EMBL/DESY, HAMBURG BEAMLINE X11 |
Synchrotron site | EMBL/DESY, Hamburg |
Beamline | X11 |
Detector technology | IMAGE PLATE |
Detector | MAR555 FLAT PANEL |
Wavelength(s) | 0.98 |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 87.143, 87.143, 73.366 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 52.610 - 1.680 |
R-factor | 0.1952 |
Rwork | 0.195 |
R-free | 0.26000 |
Structure solution method | MOLECULAR REPLACEMENT |
Refinement software | SHELXL-97 |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 52.610 | |
High resolution limit [Å] | 1.680 | 1.680 |
Number of reflections | 15847 | |
Completeness [%] | 99.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |