4KNX
Hin GlmU Bound to WG176
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | NSLS BEAMLINE X29A |
| Synchrotron site | NSLS |
| Beamline | X29A |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2009-07-15 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 1.08 |
| Spacegroup name | H 3 2 |
| Unit cell lengths | 108.745, 108.745, 326.183 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 40.790 - 1.900 |
| R-factor | 0.20516 |
| Rwork | 0.205 |
| R-free | 0.21694 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.919 |
| Data reduction software | d*TREK |
| Data scaling software | d*TREK |
| Phasing software | AMoRE |
| Refinement software | REFMAC (5.5.0046) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.970 |
| High resolution limit [Å] | 1.900 | 1.900 |
| Number of reflections | 55796 | |
| Completeness [%] | 99.8 | 100 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.1 | 293 | 2.2 M ammonium sulfate, 2% PEG400, 0.1 M MES, pH 6.1, VAPOR DIFFUSION, HANGING DROP, temperature 293K |