4KHO
Structure of the FACT complex Subunit Spt16M
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-2 |
Synchrotron site | ESRF |
Beamline | ID23-2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2009-12-18 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.873 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 61.550, 75.030, 142.720 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 45.143 - 2.000 |
R-factor | 0.209 |
Rwork | 0.208 |
R-free | 0.23570 |
Structure solution method | SAD |
RMSD bond length | 0.004 |
RMSD bond angle | 0.897 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | PHENIX (1.8_1069) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 47.800 |
High resolution limit [Å] | 2.000 |
Number of reflections | 52572 |
Completeness [%] | 99.0 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 5.5 | 298 | 6% PEG 8000, 0.1M Na-cacodylate pH 5.5, 0.2M Ca-acetate hydrate, VAPOR DIFFUSION, temperature 298.0K |