Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4K5U

Recognition of the BG-H Antigen by a Lamprey Variable Lymphocyte Receptor

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2012-10-01
DetectorRIGAKU RAXIS IV++
Wavelength(s)1.5418
Spacegroup nameP 1
Unit cell lengths57.710, 62.784, 63.366
Unit cell angles72.03, 71.39, 84.35
Refinement procedure
Resolution59.720 - 1.698
R-factor0.20566
Rwork0.206
R-free0.24661
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3e6j
RMSD bond length0.028
RMSD bond angle2.220
Data reduction softwareCrystalClear ((Rigaku))
Data scaling softwareCrystalClear ((Rigaku))
Phasing softwareAMoRE
Refinement softwareREFMAC (5.5.0102)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]59.7201.760
High resolution limit [Å]1.6981.698
Number of reflections82662
Completeness [%]93.387.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP729828.5% (w/v) PEG 3350, 0.6 M NaCl, and 0.1M Tris-HCl (pH 7.0), VAPOR DIFFUSION, HANGING DROP, temperature 298K

223166

PDB entries from 2024-07-31

PDB statisticsPDBj update infoContact PDBjnumon