Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

4I0O

Nucleoporin ELYS (aa1-494), Mus musculus

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-E
Synchrotron siteAPS
Beamline24-ID-E
Temperature [K]100
Detector technologyCCD
Collection date2008-07-18
DetectorADSC QUANTUM 315
Wavelength(s)0.9792
Spacegroup nameP 1 21 1
Unit cell lengths52.598, 78.117, 58.849
Unit cell angles90.00, 106.59, 90.00
Refinement procedure
Resolution26.525 - 1.900
R-factor0.182
Rwork0.180
R-free0.21450
Structure solution methodSAD
RMSD bond length0.012
RMSD bond angle1.429
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwareSHARP
Refinement softwarePHENIX (1.8_1063)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0001.930
High resolution limit [Å]1.9005.1601.900
Rmerge0.0840.0460.714
Number of reflections69665
<I/σ(I)>10.3
Completeness [%]98.997.797
Redundancy2.92.92.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1under oil6.5292Bis-Tris/HCl, PEG 3350, ammonium acetate, Octyl-beta-D-glucopyranoside, pH 6.5, under oil, temperature 292K

229183

PDB entries from 2024-12-18