Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 6C1 |
| Synchrotron site | PAL/PLS |
| Beamline | 6C1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2008-11-14 |
| Detector | ADSC QUANTUM 210 |
| Wavelength(s) | 1.2300 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 70.697, 71.143, 87.373 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 20.030 - 1.400 |
| R-factor | 0.1422 |
| Rwork | 0.138 |
| R-free | 0.17860 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 3cmj |
| RMSD bond length | 0.023 |
| RMSD bond angle | 1.846 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | CNS |
| Refinement software | REFMAC (5.5.0110) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.030 | 1.450 |
| High resolution limit [Å] | 1.400 | 1.400 |
| Number of reflections | 82773 | |
| Completeness [%] | 95.2 | 88.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 295 | 0.1M Tris, pH 7.0-7.4, 0.8M Na/K tartaric acid, VAPOR DIFFUSION, HANGING DROP, temperature 295K, temperature 295.0K |