4HQP
Alpha7 nicotinic receptor chimera and its complex with Alpha bungarotoxin
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 8.2.1 |
Synchrotron site | ALS |
Beamline | 8.2.1 |
Temperature [K] | 200 |
Detector technology | CCD |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1 |
Spacegroup name | P 65 2 2 |
Unit cell lengths | 142.150, 142.150, 518.135 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 45.800 - 3.510 |
R-factor | 0.311 |
Rwork | 0.311 |
R-free | 0.32100 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.004 |
RMSD bond angle | 1.000 |
Refinement software | CNS (1.3) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 45.800 |
High resolution limit [Å] | 3.500 |
Number of reflections | 38979 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | ||||
1 | ||||
1 |