4HKX
Influenza hemagglutinin in complex with CH67 Fab
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-E |
| Synchrotron site | APS |
| Beamline | 24-ID-E |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2012-02-17 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.97919 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 181.099, 69.815, 80.343 |
| Unit cell angles | 90.00, 107.33, 90.00 |
Refinement procedure
| Resolution | 35.111 - 2.500 |
| R-factor | 0.1883 |
| Rwork | 0.187 |
| R-free | 0.21910 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.087 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.7.3_928) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 2.000 |
| Number of reflections | 60500 |
| Completeness [%] | 91.9 |
| Redundancy | 6.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 295 | 46% PEG400, 100 mM Tris, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 295K |