4HHQ
Serum paraoxonase-1 by directed evolution with the H115Q and H134Q mutations
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID14-1 |
Synchrotron site | ESRF |
Beamline | ID14-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2008-07-14 |
Detector | ADSC QUANTUM 210 |
Wavelength(s) | 0.979 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 93.789, 93.789, 144.602 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 39.340 - 2.300 |
R-factor | 0.17871 |
Rwork | 0.177 |
R-free | 0.21810 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.029 |
RMSD bond angle | 2.191 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | REFMAC (5.6.0111) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 39.340 | 2.380 |
High resolution limit [Å] | 2.300 | 2.300 |
Rmerge | 0.062 | 0.483 |
Number of reflections | 27832 | |
<I/σ(I)> | 30.93 | 4.2 |
Completeness [%] | 100.0 | 100 |
Redundancy | 13.5 | 8.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 292 | 20% PEG 3350, 0.2M NaBr, 0.1M Bis-tris propane , pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 292K |