Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4HGK

Shark IgNAR variable domain

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]298
Detector technologyIMAGE PLATE
DetectorMAR scanner 300 mm plate
Wavelength(s)1.0
Spacegroup nameP 32 2 1
Unit cell lengths127.980, 127.980, 151.760
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution52.055 - 3.040
R-factor0.2387
Rwork0.237
R-free0.26630
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1ha2
RMSD bond length0.008
RMSD bond angle1.100
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwarePHASER
Refinement softwareBUSTER (2.9.3)
Data quality characteristics
 Overall
Low resolution limit [Å]52.055
High resolution limit [Å]3.040
Rmerge0.220
Number of reflections25935
Completeness [%]93.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.629116% PEG 2000 MME, 100 mM sodium acetate pH 4.6, VAPOR DIFFUSION, HANGING DROP, temperature 291K

223166

PDB entries from 2024-07-31