4H9H
Radiation damage study of lysozyme - 0.98 MGy
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL9-2 |
Synchrotron site | SSRL |
Beamline | BL9-2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-02-12 |
Detector | MARMOSAIC 325 mm CCD |
Wavelength(s) | 1.0332 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 78.773, 78.773, 36.870 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 26.917 - 1.200 |
R-factor | 0.1915 |
Rwork | 0.191 |
R-free | 0.20200 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.148 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | MOLREP |
Refinement software | PHENIX (1.7.2_862) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 1.220 |
High resolution limit [Å] | 1.200 | 3.260 | 1.200 |
Rmerge | 0.032 | 0.018 | 0.311 |
Number of reflections | 36618 | ||
<I/σ(I)> | 15.3 | ||
Completeness [%] | 99.3 | 93.1 | 100 |
Redundancy | 4.5 | 4.4 | 4.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 4.8 | 298 | 7.5% sodium chloride, 100 mM sodium acetate pH 4.8, 25% ethylene glycol, vapor diffusion, hanging drop, temperature 298K |