4H8Z
Radiation damage study of lysozyme - 0.21 MGy
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL9-2 |
Synchrotron site | SSRL |
Beamline | BL9-2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-02-12 |
Detector | MARMOSAIC 325 mm CCD |
Wavelength(s) | 1.0332 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 78.757, 78.757, 36.857 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 26.909 - 1.200 |
R-factor | 0.1913 |
Rwork | 0.191 |
R-free | 0.20500 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6lyz |
RMSD bond length | 0.006 |
RMSD bond angle | 1.094 |
Data reduction software | HKL-2000 |
Data scaling software | SCALA |
Phasing software | MOLREP |
Refinement software | PHENIX (1.7.2_862) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.232 |
High resolution limit [Å] | 1.200 | 1.200 |
Rmerge | 0.032 | 0.280 |
Number of reflections | 36830 | |
<I/σ(I)> | 43.2 | 22.95 |
Completeness [%] | 97.9 | 100 |
Redundancy | 4.5 | 4.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 4.8 | 298 | 7.5% sodium chloride, 100 mM sodium acetate pH 4.8, 25% ethylene glycol, VAPOR DIFFUSION, HANGING DROP, temperature 298K |