Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4H8Z

Radiation damage study of lysozyme - 0.21 MGy

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL9-2
Synchrotron siteSSRL
BeamlineBL9-2
Temperature [K]100
Detector technologyCCD
Collection date2011-02-12
DetectorMARMOSAIC 325 mm CCD
Wavelength(s)1.0332
Spacegroup nameP 43 21 2
Unit cell lengths78.757, 78.757, 36.857
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution26.909 - 1.200
R-factor0.1913
Rwork0.191
R-free0.20500
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6lyz
RMSD bond length0.006
RMSD bond angle1.094
Data reduction softwareHKL-2000
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwarePHENIX (1.7.2_862)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.232
High resolution limit [Å]1.2001.200
Rmerge0.0320.280
Number of reflections36830
<I/σ(I)>43.222.95
Completeness [%]97.9100
Redundancy4.54.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.82987.5% sodium chloride, 100 mM sodium acetate pH 4.8, 25% ethylene glycol, VAPOR DIFFUSION, HANGING DROP, temperature 298K

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon