Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4H8H

MUTB inactive double mutant E254Q-D415N

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-2
Synchrotron siteESRF
BeamlineID14-2
Temperature [K]100
Detector technologyCCD
Collection date2009-07-22
DetectorADSC QUANTUM 4
Wavelength(s)0.93300
Spacegroup nameP 1 21 1
Unit cell lengths62.930, 84.410, 118.970
Unit cell angles90.00, 95.94, 90.00
Refinement procedure
Resolution44.900 - 2.000
R-factor0.1831
Rwork0.181
R-free0.22780
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1zjb
RMSD bond length0.004
RMSD bond angle0.861
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.8_1069))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.9002.200
High resolution limit [Å]2.0002.000
Number of reflections83234
<I/σ(I)>13.343.4
Completeness [%]99.498
Redundancy4.24.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP62920.2M AMMONIUM SULFATE, 20% PEG3350, pH 6, VAPOR DIFFUSION, HANGING DROP, temperature 292K

221051

PDB entries from 2024-06-12

PDB statisticsPDBj update infoContact PDBjnumon