Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL12-2
Synchrotron siteSSRL
BeamlineBL12-2
Temperature [K]90
Detector technologyPIXEL
Collection date2012-03-01
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.5418, 1.5621, 1.7321
Spacegroup nameP 2 21 21
Unit cell lengths38.720, 61.550, 96.290
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution37.920 - 1.750
R-factor0.22434
Rwork0.221
R-free0.28104
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2qlg
RMSD bond length0.022
RMSD bond angle1.999
Data reduction softwareiMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareREFMAC (5.5.0109)
Data quality characteristics
 Overall
Low resolution limit [Å]37.920
High resolution limit [Å]1.750
Number of reflections22710
Completeness [%]95.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.52930.3 uL + 0.3 uL drops, precipitant: 200 mM sodium cacodylate, 100 mM Tris-HCl, pH 8.5, 30% (w/v) PEG4000, VAPOR DIFFUSION, SITTING DROP, temperature 293K

225946

PDB entries from 2024-10-09