4H0W
Bismuth bound human serum transferrin
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-07-18 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.9200 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 73.907, 90.165, 111.032 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 36.950 - 2.400 |
R-factor | 0.197 |
Rwork | 0.194 |
R-free | 0.25600 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3qyt |
RMSD bond length | 0.008 |
RMSD bond angle | 1.123 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | REFMAC (5.5.0109) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.490 |
High resolution limit [Å] | 2.400 | 2.400 |
Rmerge | 0.113 | 0.597 |
Number of reflections | 29392 | |
<I/σ(I)> | 9.2 | |
Completeness [%] | 99.6 | 100 |
Redundancy | 7 | 7.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.4 | 271 | 0.01M HEPES, 15% PEG3000, PH 7.4, VAPOR DIFFUSION, SITTING DROP, temperature 271K |