4GNB
human SMP30/GNL
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PHOTON FACTORY BEAMLINE BL-5A |
Synchrotron site | Photon Factory |
Beamline | BL-5A |
Temperature [K] | 95 |
Detector technology | CCD |
Collection date | 2010-05-24 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1.0000 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 64.500, 50.786, 86.563 |
Unit cell angles | 90.00, 100.24, 90.00 |
Refinement procedure
Resolution | 19.531 - 1.500 |
R-factor | 0.1907 |
Rwork | 0.189 |
R-free | 0.21810 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3g4e |
RMSD bond length | 0.007 |
RMSD bond angle | 1.144 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | MOLREP |
Refinement software | PHENIX ((phenix.refine: 1.8_1069)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 1.580 |
High resolution limit [Å] | 1.500 | 1.500 |
Number of reflections | 87006 | |
Completeness [%] | 98.3 | 96 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 293 | 28% PEG6000, 100mM Tris-HCl, 5mM CaCl2, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 293K |