4FQL
Influenza B HA Antibody (Fab) CR8033
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.2 |
Synchrotron site | ALS |
Beamline | 5.0.2 |
Detector technology | CCD |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 1.00000 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 136.200, 55.000, 80.800 |
Unit cell angles | 90.00, 121.20, 90.00 |
Refinement procedure
Resolution | 40.245 - 1.898 |
R-factor | 0.1962 |
Rwork | 0.194 |
R-free | 0.23110 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3n9g |
RMSD bond length | 0.007 |
RMSD bond angle | 1.177 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: 1.7.2_869)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 69.113 | 2.000 |
High resolution limit [Å] | 1.898 | 1.898 |
Number of reflections | 40203 | |
<I/σ(I)> | 6.9 | 2.6 |
Completeness [%] | 98.0 | 98.2 |
Redundancy | 3.8 | 3.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 295 | 200 mM zinc acetate, 10% PEG8000, 100 mM MES, pH 6.0, VAPOR DIFFUSION, SITTING DROP, temperature 295K |