Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4F92

Brr2 Helicase Region S1087L

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.2
Synchrotron siteBESSY
Beamline14.2
Temperature [K]100
Detector technologyCCD
Collection date2010-08-17
DetectorRAYONIX MX225HE
Wavelength(s)0.91841
Spacegroup nameC 1 2 1
Unit cell lengths146.148, 149.541, 141.324
Unit cell angles90.00, 120.33, 90.00
Refinement procedure
Resolution35.320 - 2.662
R-factor0.2142
Rwork0.212
R-free0.25920
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.005
RMSD bond angle0.987
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareMOLREP
Refinement softwarePHENIX ((phenix.refine: 1.7.3_928))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.700
High resolution limit [Å]2.6502.650
Number of reflections74339
<I/σ(I)>1.1
Completeness [%]99.799.7
Redundancy2.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5293.150.1 M sodium citrate, 1.2 M sodium Malonate, pH 5.0, VAPOR DIFFUSION, SITTING DROP, temperature 293.15K

227111

PDB entries from 2024-11-06

PDB statisticsPDBj update infoContact PDBjnumon