Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4ETD

Lysozyme, room-temperature, rotating anode, 0.0026 MGy

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007 HF
Temperature [K]293
Detector technologyIMAGE PLATE
Collection date2012-04-17
DetectorMAR scanner 345 mm plate
Wavelength(s)1.5418
Spacegroup nameP 43 21 2
Unit cell lengths79.180, 79.180, 38.100
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution34.332 - 1.904
R-factor0.1625
Rwork0.161
R-free0.19180
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.006
RMSD bond angle1.017
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX
Refinement softwarePHENIX ((phenix.refine: 1.7.2_869))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]36.0002.000
High resolution limit [Å]1.9001.900
Number of reflections9525
Completeness [%]95.292.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION293grown in Linbro plates in hanging or sitting drop geometry. Drops of equal volume of protein (20 mg/ml) and reservoir solution (1 M NaAc pH 3.0, 9-10 % NaCl, 6 % PEG 6000) were mixed. For the measurements, the crystals were equilibrated in 1 M NaAc pH 3.4, 10 % NaCl, VAPOR DIFFUSION, temperature 293K

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon