4EKH

Final Thaumatin Structure for Radiation Damage Experiment at 100 K

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCHESS BEAMLINE F1
Synchrotron siteCHESS
BeamlineF1
Temperature [K]100
Detector technologyCCD
Collection date2010-06-22
DetectorADSC QUANTUM 270
Wavelength(s)0.917
Spacegroup nameP 41 21 2
Unit cell lengths57.510, 57.510, 149.920
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution20.740 - 1.750
R-factor0.1813
Rwork0.180
R-free0.21170
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.100
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareBUSTER (2.8.0)
Refinement softwareBUSTER-TNT
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0001.810
High resolution limit [Å]1.7503.7701.750
Rmerge0.1100.0610.908
Number of reflections37321
<I/σ(I)>8.7
Completeness [%]99.998.9100
Redundancy76.46.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.8298sodium potassium tartrate, pH 6.8, VAPOR DIFFUSION, HANGING DROP, temperature 298K

219140

PDB entries from 2024-05-01