4EIP
Native and K252c bound RebC-10x
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-E |
| Synchrotron site | APS |
| Beamline | 24-ID-E |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2009-07-14 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.97910 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 64.305, 78.593, 125.723 |
| Unit cell angles | 90.00, 99.87, 90.00 |
Refinement procedure
| Resolution | 41.365 - 2.332 |
| R-factor | 0.2158 |
| Rwork | 0.213 |
| R-free | 0.26000 |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.089 |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | PHENIX (1.7.3_928) |
| Refinement software | PHENIX (1.7.3_928) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.380 |
| High resolution limit [Å] | 2.300 | 2.300 |
| Number of reflections | 51631 | |
| Completeness [%] | 99.3 | 98.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 298 | 100 mM ammonium fluoride, 20% PEG 3350, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K |