Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4E8X

Lambda-[Ru(TAP)2(dppz-(Me)2)]2+ bound to d(CCGGCGCCGG)2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I02
Synchrotron siteDiamond
BeamlineI02
Temperature [K]100
Detector technologyCCD
Collection date2012-03-13
DetectorADSC QUANTUM 315r
Wavelength(s)0.9795
Spacegroup nameP 43 21 2
Unit cell lengths47.090, 47.090, 34.130
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution33.300 - 2.180
R-factor0.23521
Rwork0.233
R-free0.28370
Structure solution methodSAD
RMSD bond length0.013
RMSD bond angle2.694
Refinement softwareREFMAC (5.6.0117)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.0902.240
High resolution limit [Å]2.1802.180
Number of reflections2189
Completeness [%]98.699.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP72771ul 2mM DNA, 1ul 2mM lambda-[Ru(TAP)2(dppz-(Me)2)]Cl2, 6ul 10% 2-methyl-2,4-pentanediol, 40mM sodium cacodylate, 12mM spermine tetra-HCl, 80mM potassium chloride, 20mM barium chloride, pH 7, VAPOR DIFFUSION, SITTING DROP, temperature 277K

223166

PDB entries from 2024-07-31

PDB statisticsPDBj update infoContact PDBjnumon