4E7J

PFV integrase Target Capture Complex, Apo form (TCC-Apo), at 3.15 A resolution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I02
Synchrotron siteDiamond
BeamlineI02
Temperature [K]100
Detector technologyCCD
Collection date2010-10-29
DetectorADSC QUANTUM 315r
Wavelength(s)0.9763
Spacegroup nameP 41 21 2
Unit cell lengths159.339, 159.339, 127.197
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution36.976 - 3.150
R-factor0.2242
Rwork0.222
R-free0.26380
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3os2
RMSD bond length0.009
RMSD bond angle1.443
Data reduction softwareXDS
Data scaling softwareSCALA
Refinement softwarePHENIX ((phenix.refine: 1.7.3_928))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]40.0003.320
High resolution limit [Å]3.1503.150
Rmerge0.1350.461
Number of reflections28471
<I/σ(I)>5.82
Completeness [%]99.099.9
Redundancy3.73.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION7.429134% PEG-400, 180MM LI2SO4,2.5MM EDTA, 100MM TRIS-HCL, pH 7.4, VAPOR DIFFUSION, temperature 291K