Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4DLY

Set 1 CaCl2/DTT, ordered off

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-BM
Synchrotron siteAPS
Beamline22-BM
Temperature [K]100
Detector technologyCCD
DetectorMARRESEARCH
Wavelength(s)1.0
Spacegroup nameH 3 2
Unit cell lengths88.207, 88.207, 134.142
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution28.226 - 1.570
R-factor0.1599
Rwork0.158
R-free0.17900
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.272
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwarePHENIX
Refinement softwarePHENIX (1.6.1_336)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0001.600
High resolution limit [Å]1.5704.2601.570
Rmerge0.0640.0440.295
Number of reflections28221
<I/σ(I)>12.1
Completeness [%]99.699.492.9
Redundancy10.910.49
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.529820% PEG 3350, 200 mM CaCl2, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 298K

222415

PDB entries from 2024-07-10

PDB statisticsPDBj update infoContact PDBjnumon