4DEZ
Structure of MsDpo4
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE BM14 |
| Synchrotron site | ESRF |
| Beamline | BM14 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2010-07-01 |
| Detector | MAR CCD 165 mm |
| Wavelength(s) | 0.96 |
| Spacegroup name | P 65 2 2 |
| Unit cell lengths | 125.230, 125.230, 142.520 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 50.000 - 2.600 |
| Rwork | 0.211 |
| R-free | 0.23800 |
| Structure solution method | SAD |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | SHELXS |
| Refinement software | CNS (1.2) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.690 |
| High resolution limit [Å] | 2.600 | 2.600 |
| Rmerge | 0.091 | 0.474 |
| Number of reflections | 20393 | |
| <I/σ(I)> | 23.49 | 4.5 |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 7.2 | 7.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.2 | 298 | 2.4 M NaCl with 0.1 M Na/K phosphate (pH=6.2), VAPOR DIFFUSION, HANGING DROP, temperature 298K |