4CYI
Chaetomium thermophilum Pan3
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND |
Synchrotron site | Diamond |
Beamline | I03 |
Temperature [K] | 100 |
Spacegroup name | P 1 |
Unit cell lengths | 51.520, 146.040, 149.930 |
Unit cell angles | 89.81, 81.13, 82.77 |
Refinement procedure
Resolution | 52.212 - 2.420 |
R-factor | 0.1925 |
Rwork | 0.190 |
R-free | 0.23430 |
Structure solution method | SAD |
Starting model (for MR) | NONE |
RMSD bond length | 0.004 |
RMSD bond angle | 0.875 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | SHARP |
Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 52.210 | 2.480 |
High resolution limit [Å] | 2.420 | 2.420 |
Rmerge | 0.040 | 0.360 |
Number of reflections | 160956 | |
<I/σ(I)> | 14.3 | 2.4 |
Completeness [%] | 98.5 | 98 |
Redundancy | 7.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | SEE MANUASCRIPT |