4CMY
Chlorobium tepidum Ferritin
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I24 |
Synchrotron site | Diamond |
Beamline | I24 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Detector | DECTRIS PILATUS 6M |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 123.310, 190.370, 242.070 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 103.710 - 2.590 |
R-factor | 0.19421 |
Rwork | 0.193 |
R-free | 0.21788 |
Structure solution method | OTHER |
Starting model (for MR) | NONE |
RMSD bond length | 0.014 |
RMSD bond angle | 1.601 |
Refinement software | REFMAC (5.7.0029) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 100.000 | 2.730 |
High resolution limit [Å] | 2.590 | 2.590 |
Rmerge | 0.150 | 0.700 |
Number of reflections | 169035 | |
<I/σ(I)> | 2.2 | |
Completeness [%] | 100.0 | 100 |
Redundancy | 6.6 | 5.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |