4CKT

PIH1 N-terminal domain

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2012-09-30
DetectorDECTRIS PILATUS 6M
Spacegroup nameP 21 21 21
Unit cell lengths50.020, 62.150, 114.290
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution54.599 - 3.000
R-factor0.2267
Rwork0.224
R-free0.28140
Structure solution methodSAD
Starting model (for MR)NONE
RMSD bond length0.011
RMSD bond angle1.838
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwareSHELX
Refinement softwarePHENIX ((PHENIX.REFINE))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]61.6703.140
High resolution limit [Å]3.0603.060
Rmerge0.1200.520
Number of reflections68364
<I/σ(I)>15.42.5
Completeness [%]90.156.4
Redundancy10.84.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
17pH 7

222926

PDB entries from 2024-07-24