4C3D
HRSV M2-1, P422 crystal form
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I02 |
Synchrotron site | Diamond |
Beamline | I02 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-01-31 |
Detector | DECTRIS PILATUS 6M |
Spacegroup name | P 4 2 2 |
Unit cell lengths | 102.275, 102.275, 90.993 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 45.740 - 2.520 |
R-factor | 0.21351 |
Rwork | 0.211 |
R-free | 0.26323 |
Structure solution method | SAD |
Starting model (for MR) | NONE |
RMSD bond length | 0.013 |
RMSD bond angle | 1.460 |
Data reduction software | MOSFLM |
Data scaling software | Aimless |
Phasing software | AutoSol |
Refinement software | REFMAC (5.7.0032) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 45.740 | 2.610 |
High resolution limit [Å] | 2.520 | 2.520 |
Rmerge | 0.100 | 0.650 |
Number of reflections | 16695 | |
<I/σ(I)> | 14.8 | 3.8 |
Completeness [%] | 98.9 | 91.2 |
Redundancy | 30 | 6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 10 | 30 % (V/V) PEG 400, 0.01 M CDCL2, 0.1 M CAPS PH 10 |