4AUR

LeoA bacterial dynamin GTPase from ETEC

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I02
Synchrotron siteDiamond
BeamlineI02
Temperature [K]100
Detector technologyCCD
Collection date2010-04-11
DetectorADSC CCD
Spacegroup nameC 1 2 1
Unit cell lengths185.515, 53.659, 73.949
Unit cell angles90.00, 96.65, 90.00
Refinement procedure
Resolution50.000 - 2.700
R-factor0.21631
Rwork0.213
R-free0.28915
Structure solution methodMAD
Starting model (for MR)NONE
RMSD bond length0.011
RMSD bond angle1.444
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareSOLVE
Refinement softwareREFMAC (5.7.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0002.850
High resolution limit [Å]2.7002.700
Rmerge0.0900.420
Number of reflections17775
<I/σ(I)>8.22.2
Completeness [%]97.893.8
Redundancy3.33.1
Crystallization Conditions