Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

4ZZC

The GLIC pentameric Ligand-Gated Ion Channel open form complexed to xenon

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE BM30A
Synchrotron siteESRF
BeamlineBM30A
Temperature [K]100
Detector technologyCCD
Collection date2013-06-20
DetectorADSC QUANTUM 315r
Wavelength(s)1.182
Spacegroup nameC 1 2 1
Unit cell lengths180.000, 132.820, 159.150
Unit cell angles90.00, 101.88, 90.00
Refinement procedure
Resolution25.000 - 3.100
R-factor0.2089
Rwork0.208
R-free0.22750
RMSD bond length0.009
RMSD bond angle1.040
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwareREFMAC
Refinement softwareBUSTER (2.11.4)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.0003.270
High resolution limit [Å]3.1003.100
Rmerge0.665
<I/σ(I)>2
Completeness [%]99.9
Redundancy3.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP29012-15% PEG4000 0.1M Na Acetate pH4 0.4M NaSCN 15% glycerol 5% DMSO

229380