4YJZ
Human antibody H2526 in complex with influenza hemagglutinin H1 Solomon Islands/03/2006
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 8.2.2 |
Synchrotron site | ALS |
Beamline | 8.2.2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-02-06 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.99998 |
Spacegroup name | I 2 2 2 |
Unit cell lengths | 63.149, 153.166, 177.628 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.770 |
High resolution limit [Å] | 2.720 | 2.720 |
Rmerge | 0.070 | 0.648 |
Number of reflections | 23649 | |
<I/σ(I)> | 2.892 | |
Completeness [%] | 99.8 | 100 |
Redundancy | 5.7 | 5.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 293 | 0.1M HEPES, 30% PEG 400 and 0.1M ammonium sulfate |