4Y7A
Factor Xa complex with GTC000422
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SRS BEAMLINE PX9.6 |
| Synchrotron site | SRS |
| Beamline | PX9.6 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2001-03-28 |
| Detector | ADSC QUANTUM 4 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 57.160, 73.477, 80.377 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 20.000 - 1.990 |
| R-factor | 0.1913 |
| Rwork | 0.189 |
| R-free | 0.23620 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1ezq |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.349 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 26.630 |
| High resolution limit [Å] | 1.990 |
| Rmerge | 0.085 |
| Number of reflections | 23605 |
| <I/σ(I)> | 11.8 |
| Completeness [%] | 99.3 |
| Redundancy | 4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 18% PEG 6000, 100 mM MES PH 5.75, 10 mM calcium chloride |