4X2O

Sac3N peptide bound to Mex67:Mtr2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-4
Synchrotron siteESRF
BeamlineID14-4
Temperature [K]100
Detector technologyCCD
Collection date2013-09-28
DetectorADSC QUANTUM 315r
Wavelength(s)0.9763
Spacegroup nameP 21 21 21
Unit cell lengths56.724, 73.007, 93.182
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.453 - 1.850
R-factor0.1637
Rwork0.162
R-free0.20120
RMSD bond length0.010
RMSD bond angle1.225
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.9_1692))
Data quality characteristics
 Overall
Low resolution limit [Å]48.453
High resolution limit [Å]1.850
Number of reflections33498
<I/σ(I)>15.5
Completeness [%]99.3
Redundancy4.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29120 % PEG 6000, 1M LiCl, 0.1M MES pH 6.0. See manuscript for details.