Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4X2K

Selection of fragments for kinase inhibitor design: decoration is key

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2007-12-13
DetectorPSI PILATUS 6M
Wavelength(s)1.00000
Spacegroup nameP 21 21 21
Unit cell lengths42.310, 77.510, 90.200
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution22.540 - 1.690
R-factor0.1668
Rwork0.153
R-free0.18420
RMSD bond length0.010
RMSD bond angle1.020
Data reduction softwareXDS
Data scaling softwareXSCALE
Refinement softwareBUSTER (2.11.4)
Data quality characteristics
 Overall
Low resolution limit [Å]44.540
High resolution limit [Å]1.680
Number of reflections32921
<I/σ(I)>19
Completeness [%]98.2
Redundancy12.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52930.1 M Tris-HCl, 240 mM Li2SO4, 24% PEG 4000, pH 7.5

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon