Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4WHD

Human CEACAM1 N-domain homodimer

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 19-ID
Synchrotron siteAPS
Beamline19-ID
Temperature [K]100
Detector technologyCCD
Collection date2011-08-17
DetectorADSC QUANTUM 315r
Wavelength(s)1.0
Spacegroup nameP 4 21 2
Unit cell lengths107.573, 107.573, 63.960
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution76.070 - 2.500
R-factor0.1872
Rwork0.183
R-free0.22590
RMSD bond length0.011
RMSD bond angle1.647
Refinement softwareREFMAC (5.8.0073)
Data quality characteristics
 Overall
Low resolution limit [Å]76.070
High resolution limit [Å]2.500
Number of reflections13472
<I/σ(I)>18.63
Completeness [%]99.0
Redundancy1.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.2295PEG 3000, NaCl, Phosphate-Citrate

219869

PDB entries from 2024-05-15