Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4WFE

Human TRAAK K+ channel in a K+ bound conductive conformation

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-D
Synchrotron siteAPS
Beamline23-ID-D
Temperature [K]100
Detector technologyCCD
Collection date2012-11-07
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)1.0332
Spacegroup nameP 1 21 1
Unit cell lengths80.795, 138.522, 96.843
Unit cell angles90.00, 95.08, 90.00
Refinement procedure
Resolution48.200 - 2.500
R-factor0.20086
Rwork0.199
R-free0.23410
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4i9w
RMSD bond length0.008
RMSD bond angle1.058
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0073)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.2002.540
High resolution limit [Å]2.5002.500
Number of reflections69456
<I/σ(I)>22.60.9
Completeness [%]99.699.8
Redundancy3.83.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.827750 mM Tris pH 8.8, 200 mM CaCl2, 27-30% (vol/vol) PEG400, 4% (vol/vol) polypropylene glycol

219869

PDB entries from 2024-05-15