4WFE
Human TRAAK K+ channel in a K+ bound conductive conformation
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-D |
Synchrotron site | APS |
Beamline | 23-ID-D |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-11-07 |
Detector | MARMOSAIC 300 mm CCD |
Wavelength(s) | 1.0332 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 80.795, 138.522, 96.843 |
Unit cell angles | 90.00, 95.08, 90.00 |
Refinement procedure
Resolution | 48.200 - 2.500 |
R-factor | 0.20086 |
Rwork | 0.199 |
R-free | 0.23410 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4i9w |
RMSD bond length | 0.008 |
RMSD bond angle | 1.058 |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0073) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.200 | 2.540 |
High resolution limit [Å] | 2.500 | 2.500 |
Number of reflections | 69456 | |
<I/σ(I)> | 22.6 | 0.9 |
Completeness [%] | 99.6 | 99.8 |
Redundancy | 3.8 | 3.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.8 | 277 | 50 mM Tris pH 8.8, 200 mM CaCl2, 27-30% (vol/vol) PEG400, 4% (vol/vol) polypropylene glycol |