4WE8
The crystal structure of hemagglutinin of influenza virus A/Victoria/361/2011
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 22-ID |
| Synchrotron site | APS |
| Beamline | 22-ID |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2013-03-16 |
| Detector | MAR scanner 345 mm plate |
| Wavelength(s) | 1.0 |
| Spacegroup name | H 3 2 |
| Unit cell lengths | 100.911, 100.911, 383.361 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 34.156 - 2.100 |
| R-factor | 0.1923 |
| Rwork | 0.190 |
| R-free | 0.22730 |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.931 |
| Refinement software | PHENIX ((phenix.refine: 1.8_1069)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 2.100 |
| Number of reflections | 43789 |
| <I/σ(I)> | 37.1 |
| Completeness [%] | 98.5 |
| Redundancy | 5.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | MICROBATCH | 10.5 | 293 | 0.1M CAPS:NaOH, 30% PEG 400 |