Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2011-05-11 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 1.000 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 210.190, 451.050, 621.990 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 153.762 - 3.100 |
R-factor | 0.2008 |
Rwork | 0.201 |
R-free | 0.23990 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.015 |
RMSD bond angle | 0.690 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHENIX |
Refinement software | PHENIX ((phenix.refine: dev_810)) |
Data quality characteristics
Overall | Inner shell | |
Low resolution limit [Å] | 300.000 | 300.000 |
High resolution limit [Å] | 3.000 | 50.000 |
Rmerge | 0.332 | 0.049 |
Number of reflections | 1165415 | 279 |
<I/σ(I)> | 12.52 | 48.52 |
Completeness [%] | 100.0 | 88.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 4% PEG20K, 4% PEGMME 550, 100mM Tris/HAc, 200mM KSCN, pH 7.5, vapor diffusion, hanging drop, temperature 293K |