4UCG
NmeDAH7PS R126S variant
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX1 |
Synchrotron site | Australian Synchrotron |
Beamline | MX1 |
Temperature [K] | 120 |
Detector technology | CCD |
Collection date | 2013-10-05 |
Detector | ADSC CCD |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 78.949, 132.660, 147.722 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 98.700 - 2.000 |
R-factor | 0.18206 |
Rwork | 0.180 |
R-free | 0.22000 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4hsn |
RMSD bond length | 0.010 |
RMSD bond angle | 1.357 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER (MR) |
Refinement software | REFMAC (5.8.0073) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.030 | 2.030 |
High resolution limit [Å] | 2.000 | 2.000 |
Rmerge | 0.150 | |
Number of reflections | 105375 | |
<I/σ(I)> | 15.2 | 1.5 |
Completeness [%] | 100.0 | 99.9 |
Redundancy | 14.8 | 14.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 7.3 | 0.1 M TRIS HCL (PH 7.3), 0.2 M TRIMETHYL-AMINO-N-OXIDE (TMAO), 600UM MNSO4 AND 15-20% (W/V) PEG 2000MME |